Morecare Coral – Electric Rotating Homecare Bed with 90° Chair Transfer Function
An electric homecare bed with 90° right-side chair rotation, height-adjustable positioning and caregiver controls to prepare suitable adults for assisted bed exits.





Delivery
Support
Eligibility
Support
Product Information
Everything you need to know about this product.
Supported Chair Positioning for Assisted Bed Exits
When a person has difficulty moving from lying to sitting and preparing to get out of bed, repositioning can place considerable demands on caregivers. Morecare Coral combines an electrically adjustable homecare bed with a powered 90° right-side chair-rotation mechanism.
After the backrest and leg section are placed in the required positions, the seating platform rotates toward the user's right, bringing the person into a chair-like position near the side of the bed. This can provide a more practical starting position for an assessed, caregiver-assisted transfer.
- Right-Side Chair Rotation: Moves the supported seating arrangement through 90° towards the user's right; it is not a mechanical patient lift.
- Electric Hi-Low Adjustment: Changes the height from approximately 20 to 34 inches, measured from floor to the top of the supplied mattress.
- Multiple Bed Positions: Electric backrest elevation, leg-rest elevation, Trendelenburg and reverse Trendelenburg adjustments accommodate selected resting and care activities.
- Caregiver Controls: Two wired handheld remotes operate rotation separately from the other powered functions.
- Homecare Construction: A steel frame, upholstered exterior, removable side rails and eight lockable castors support everyday installation and supervised care.
Coral does not transfer a person into a wheelchair or independently bring them to standing. Safe use depends on the user's trunk control, transfer ability, caregiver support and available space to the right of the bed.
| Section | General Information |
|---|---|
| Product Name | Morecare Coral |
| Model | Coral |
| Product Type | Electric Rotating Homecare Bed with 90° Chair Function |
| Recommended Users | Adults and older adults above 5 ft; individual fit assessment required |
| Published Maximum User Weight | 200 kg |
| Operation | Electric, caregiver-controlled |
| Country of Origin | India |
| Section | Dimensions & Space |
| Overall Bed Length | 82 inches |
| Overall Bed Width | 38 inches |
| Electric Height Range | 20–34 inches |
| Height Measurement | Floor to top of supplied mattress |
| Minimum Rotation-Side Clearance | 42 inches of additional clear space on user's right |
| Section | Frame, Mattress & Wheels |
| Frame Construction | Steel |
| Exterior Finish | Upholstered panels |
| Side Rails | Detachable, both sides |
| Castors | 8 lockable castors |
| Included Mattress | CNC contour-cut foam mattress |
| Section | Electric Positioning |
| Electric Actuators | 5 |
| Backrest Elevation | Up to 85° |
| Leg-Rest Adjustment | Up to 45° |
| Bed Height Adjustment | Electric Hi-Low |
| Whole-Bed Tilt | Trendelenburg and reverse Trendelenburg |
| Chair Rotation | 90°, toward the user's right only |
| Rotation Preconditions | Backrest and leg rest in prescribed inclined configuration |
| Rotation at Different Heights | Available subject to approved operating sequence |
| Adjustment During Partial Rotation | Do not operate other bed positioning functions |
| Section | Controls & Electrical |
| Control System | Two wired handheld remotes |
| Rotation Control | Separate wired remote |
| Other Bed Functions | Second wired remote |
| Stop-on-Release | Yes |
| Power Supply | AC mains |
| Battery Backup | Optional; not standard |
| Power Failure Without Backup | Bed remains in its current position |
| Section | Safety, Delivery & Support |
| Movement While Occupied | Do not wheel/move bed while occupied |
| Delivery Condition | Largely assembled |
| Final Assembly | Head-end panel, foot-end panel and side rails |
| Virtual Setup Assistance | Available |
| Warranty | 12 months against qualifying manufacturing defects |
Practical Applications
Assisted Bed-Exit Preparation
Coral's right-side chair rotation brings a suitable user into a supported chair-like position near the edge of the bed. A caregiver can then perform the individually assessed transfer process without first repositioning the person into the same starting posture entirely by hand.
Preparation for Wheelchair Transfers
The chair position and adjustable bed height can help caregivers prepare for a planned transfer to a wheelchair when the user's sitting balance, lower-limb strength and transfer method permit. Coral does not lift the user into the wheelchair.
Supported Sitting and Resting
Electric backrest and leg-rest adjustment allow selected positions for conversation, reading, supervised meals and resting, subject to the user's care needs.
Caregiver-Assisted Personal Care
The adjustable bed height can provide more suitable access for washing, dressing, positioning and other daily care tasks.
Clinically Directed Bed Positioning
Trendelenburg and reverse Trendelenburg functions are available for situations in which these positions are appropriate and prescribed or recommended by a qualified professional. They should not be used as automatic or universal treatments.
Expected Practical Benefit
The objective is more flexible bed positioning and a more accessible starting position for selected assisted bed exits. The amount of caregiver effort saved and the suitability of transfers differ from person to person. Coral does not replace a hoist, physical assistance or prescribed pressure-injury care.
Who May Be Suitable
- Adults and older adults who require assistance with bed positioning and preparation for an assisted bed exit.
- Users with sufficient postural stability or appropriate caregiver support to remain positioned safely during chair rotation.
- People whose height, weight and body dimensions fit the supplied bed and mattress; the published weight limit is 200 kg and the stated recommended height is above 5 ft.
- Homes with accessible installation space and a clear right-hand side for rotation.
When Another Solution May Be Better
- A fully dependent user requiring lifting into a wheelchair may need a patient hoist or other transfer system; Coral is not a lifting or transfer hoist.
- Users with marked trunk instability, uncontrolled movements, severe contractures or complex positioning requirements need specialist assessment before considering the chair-rotation function.
- If only left-side access is available, the standard Coral rotation direction may be unsuitable; it rotates to the user's right only.
- If uninterrupted operation during power cuts is essential, discuss the optional battery backup and the manufacturer's emergency-use procedure.
- A smaller or simpler adjustable bed may be preferable when rotation is not required or room access is limited.
Measurements to Share Before Ordering
Provide user height, weight, seated balance, head and trunk control, weight-bearing ability, transfer method, caregiver availability and wheelchair dimensions where relevant.
Measure the doorway, staircase/lift access, room floor area and the area to the user's right. The standard bed measures 82 × 38 inches and requires at least 42 inches of extra right-side rotation clearance, plus appropriate space for caregivers and transfer equipment.
A Morecare fitting and installation review is recommended before purchase. A diagnosis alone does not establish transfer suitability.
Customization on Request
- Selected length and width changes may be considered after checking the bed's structure and rotation clearance.
- Upholstery colours, compatible mattress options and selected side-rail configurations can be discussed.
- Battery backup is optional, not included in the standard product.
- Any special accessories or adaptations require written confirmation of technical feasibility, price, supply and warranty implications.
Essential Safety and Operation
- Install the bed on a firm, level floor and lock all eight castors for stationary use, positioning and transfers.
- Before rotating, check at least 42 inches of free space to the user's right and remove any obstacles, furniture or equipment from the movement path.
- Set the backrest and leg section to the required inclined configuration before operating the separate rotation remote; follow the product manual for the exact sequence.
- Keep a caregiver present and monitor the user's head, trunk, limbs and any medical tubing throughout movement.
- Do not use height, backrest, leg-rest or whole-bed tilt controls while the platform is between the normal and fully rotated positions.
- Stop movement by releasing the control if an obstruction or unexpected response occurs. Never force a mechanism.
- Assess sitting balance, strength and the appropriate transfer method before trying to stand or move to a wheelchair. Coral does not lift a person into standing or into another seat.
- Do not wheel or move the bed while a person is occupying it. Do not exceed the stated 200 kg user-weight limit.
- Check side-rail positions, mattress fit and potential entrapment gaps as part of the user's individual care plan.
- Use appropriate professional guidance for Trendelenburg and reverse Trendelenburg positions, particularly where the user's medical condition makes these positions unsuitable.
Power Failure and Electrical Safety
- Use a suitable properly grounded AC power supply. Keep remotes, actuators, cables and connectors dry and away from moving parts.
- Without the optional backup, Coral remains in its current position if power fails. Ask Morecare for the applicable emergency procedure before use.
- Confirm the battery-backup specification, emergency instructions and permitted operations before purchase where power supply is unreliable.
Cleaning and Preventive Maintenance
- Clean applicable hard surfaces with a soft cloth and mild detergent, following the mattress and upholstery care instructions.
- Do not pressure-wash or use harsh solvents.
- Inspect side rails, castor brakes, fasteners, actuators, remotes, cables and the rotation mechanism regularly.
- Stop using affected functions and contact Morecare if a component is damaged, loose or operating unexpectedly.
Shipping and Delivery
- Standard orders are typically dispatched within 2–3 working days after confirmation.
- Estimated delivery is approximately 4–5 working days after dispatch, depending on the destination and carrier.
- Made-to-order configurations may need additional production time. Confirm scheduling before paying.
- Before dispatch, verify doorway width, lift/staircase access, the installation room and right-side rotation clearance.
Assembly and Setup
- Coral arrives largely assembled; the head-end panel, foot-end panel and detachable side rails need fitting.
- Free virtual installation and setup guidance is available.
- Test the brake locks, rail attachments and all permitted positioning functions after assembly before the bed is used.
10-Day Returns and Refunds
- Return Request Window: Contact Morecare within 10 days of delivery. The companywide return-request window applies to all Morecare products, including Coral, subject to published eligibility requirements.
- Restocking Fee: Approved eligible change-of-mind returns incur a 20% restocking fee.
- Return Courier Included: Return courier charges are already included within this 20% fee. No separate return-courier charge is deducted.
- Transit Damage: Report visible or concealed shipping damage as soon as possible, preferably within 48 hours of delivery, with photographs/videos and packaging details. Valid damage or defect claims are handled separately from change-of-mind returns, subject to applicable consumer rights.
- Custom Orders: The same 10-day request window applies; any product-specific eligibility conditions will be disclosed before ordering.
- Exchanges and Pre-Dispatch Cancellations: Governed by the current Morecare customer policy. Please confirm applicable terms with Morecare before placing an order.
Warranty and After-Sales Support
- Warranty: 12 months against qualifying manufacturing defects under normal use, subject to the written warranty terms and original purchase invoice.
- Usual exclusions include accidental damage, misuse, unauthorized modifications and ordinary wear, where legally applicable.
- Morecare lists lifetime virtual technical guidance by phone/video, with replacement parts and paid servicing subject to availability.
- Phone/WhatsApp: +91 63775 09047
- Full terms: Refer to the current Morecare Customer Policy Guide.
Product Showcase & Reviews
Watch clinical insights and customer experiences.
Every Choice Has a Story
Choosing the right rehabilitation equipment is about finding the right fit for your family. Read why families chose this product
FAQs related to Coral – Electric Rotating Homecare Bed with 90° Chair Transfer Function
Find quick answers to common questions about this product.
Coral may suit selected adults and older adults above 5 ft who need help with bed positioning and caregiver-assisted bed exits. The published maximum user weight is 200 kg. A fitting and transfer assessment is essential, especially when trunk control or standing ability is limited.
No. Coral rotates the supported seating platform 90° toward the user's right to prepare for an assisted bed exit. It does not lift the person into standing or transfer them into a wheelchair. An appropriate transfer method and caregiver assistance are still required.
The standard mechanism rotates toward the user's right only. The bed measures 82 × 38 inches and requires at least 42 inches of additional clear space on the rotation side, plus working space for caregivers and any transfer equipment.
It has powered backrest adjustment up to 85°, leg-rest adjustment up to 45°, electric Hi-Low adjustment from 20 to 34 inches, Trendelenburg/reverse Trendelenburg positioning and 90° right-side chair rotation. Two wired remotes control rotation and the other functions separately. Follow the approved adjustment sequence.
Coral is powered by AC mains. Without battery backup, the bed stays in its current position when power fails. Battery backup is optional and must be specified at the time of ordering; confirm its functions and emergency procedure with Morecare.
A CNC contour-cut foam mattress is included; confirm its exact thickness and cover before ordering. Coral carries a 12-month manufacturing-defect warranty under its terms. Return requests must be made within 10 days of delivery. Approved eligible change-of-mind returns incur a 20% restocking fee, which already includes return courier charges.
Need Help Finding the
Right Solution?
Our rehabilitation experts are here to help you choose the right product or create a customized solution tailored to your needs.