Morecare Snapdragon – Electric Patient Lift & Transfer Hoist with Gait Training Support
A heavy-duty electric patient lift for assisted bed-to-wheelchair transfers, selected floor-level lifting and therapist-supervised gait training, with a 300 kg manufacturer-rated capacity and both transfer and walking slings included.





Delivery
Support
Eligibility
Support
Product Information
Everything you need to know about this product.
Helping Caregivers Manage Difficult Patient Transfers
Moving a person with limited mobility from a bed into a wheelchair or another suitable care surface can require considerable physical effort. For someone unable to support their body weight during transfers, direct manual lifting may be difficult for both the person and their caregiver.
The Morecare Snapdragon is a heavy-duty electric patient lift and transfer hoist designed to provide powered assistance during planned patient-handling activities.
Using a removable lithium-ion battery, electric linear actuator and wired two-button controller, Snapdragon allows a trained caregiver to raise and lower a person in an appropriately fitted sling.
Beyond daily transfers, the included walking sling enables selected therapist-supervised standing and gait-training activities.
How Snapdragon Helps
- Assisted Bed-to-Wheelchair Transfers: The powered lifting mechanism helps caregivers transfer a user between compatible care surfaces using the included transfer sling.
- Selected Floor-Level Lifting: The lifting hook has an approximate height range of 2–7.5 ft from the floor, allowing selected floor-level lifting applications under approved handling procedures.
- Two Slings Included: A transfer sling and walking sling are supplied as standard, allowing different handling and rehabilitation tasks without purchasing these two slings separately.
- Supported Standing and Gait Practice: The walking sling can provide lifting support for selected therapist-supervised standing or stepping activities.
- Adjustable Base: Foot-operated base-width adjustment helps the hoist approach suitable beds, wheelchairs and other care equipment.
- Battery-Powered Operation: The removable lithium-ion battery allows electric lifting without a continuous mains connection during operation.
- Heavy-Duty Construction: The 2 mm HR-grade mild-steel frame has a powder-coated finish and a manufacturer-rated Safe Working Load of 300 kg.
Understanding the 300 kg Safe Working Load
Morecare confirms a 300 kg manufacturer-rated Safe Working Load, based on internal testing.
Both standard slings are also confirmed to have 300 kg ratings. However, the permissible load for each use must never exceed the lowest-rated sling, connection or other component in the actual configuration.
The 6000 N actuator specification is a component rating and should not be presented as independent evidence of the complete-system lifting capacity.
Suitable Applications
Snapdragon may be considered for adults with substantial transfer-assistance requirements, including selected people affected by paralysis, stroke, neurological conditions or prolonged mobility limitations.
It can also support appropriate lifting tasks in hospitals, nursing facilities, rehabilitation centres and suitably prepared homes.
Suitability depends on the user's measurements, body support requirements, correct sling selection, room dimensions and caregiver training.
Important Safety Information
Snapdragon includes an emergency-stop function but does not have emergency lowering. Before using the lift with a person, the operator must understand the manufacturer's approved assisted-recovery procedure and verify that the required assistance is available.
Snapdragon is not a mobility wheelchair or an independent walking machine. It provides powered lifting support; it does not independently control balance, stepping or the user's lower limbs.
| Section | General Information |
|---|---|
| Product Name | Morecare Snapdragon |
| Model | Snapdragon |
| Product Type | Electric Patient Lift & Transfer Hoist with Gait Training Support |
| Recommended Users | Adults requiring assisted transfers |
| Primary Applications | Bed-to-Wheelchair Transfers, Compatible Care-Surface Transfers, Floor-Level Lifting |
| Secondary Application | Therapist-Supervised Supported Standing and Gait Practice |
| Maximum Safe Working Load | 300 kg |
| Load Validation | Manufacturer Internal Testing |
| Standard Transfer Sling Capacity | 300 kg |
| Standard Walking Sling Capacity | 300 kg |
| Country of Origin | India |
| Recommended Settings | Homecare, Hospitals, Nursing Facilities, Rehabilitation Centres |
| Section | Frame & Construction |
| Frame Material | 2 mm HR-Grade Mild Steel |
| Frame Finish | Ivory White Powder Coating |
| Equipment Weight | Approximately 40 kg Including Battery |
| Base | Foot-Operated Adjustable Width |
| Boom | Foldable Configuration |
| Castors | 4 |
| Castor Brakes | All Four Castors Lockable |
| Floor Surface | Smooth, Firm, Level Indoor Flooring |
| Closed Base Width | Use Confirmed Factory Measurement Sheet |
| Open Base Width | Use Confirmed Factory Measurement Sheet |
| Under-Bed Clearance | Use Confirmed Factory Measurement Sheet |
| Overall Dimensions | Use Confirmed Factory Measurement Sheet |
| Section | Electric Lifting System |
| Lift Mechanism | Electric Linear Actuator |
| Actuator Force Rating | 6000 N |
| Hook Height Range | Approximately 2–7.5 ft from Floor |
| Power Source | Rechargeable Lithium-Ion Battery |
| Battery Type | Removable |
| Control Unit | Separate Electrical Control Box |
| Handset | Wired 2-Button Up/Down Controller |
| Battery Charger | 24V Smart Charger |
| Published Charging Time | Approximately 4 Hours |
| Actuator Ingress Protection | IP54; Applies to Actuator, Not Entire Hoist |
| Section | Safety Features |
| Maximum Rated System Load | 300 kg, Subject to Lowest-Rated Component |
| Emergency Stop | Included |
| Emergency Stop Reset | Manufacturer-Approved Reset Procedure |
| Emergency Lowering | Not Available |
| Emergency Recovery | Manufacturer-Approved Assisted-Recovery Procedure |
| Sling Attachment | Spreader Bar with Sling Attachment Points |
| Brake Procedure | Confirmed for Lifting, Lowering, Positioning and Movement; Use Approved Instructions |
| Caregiver Supervision | Required |
| Patient Lifting | Only With Correctly Fitted Approved Sling |
| Operating Environment | Level Surfaces with Adequate Clearance |
| Section | Standard Sling System |
| Transfer Sling | Included |
| Walking Sling | Included |
| Transfer Sling Rated Capacity | 300 kg |
| Walking Sling Rated Capacity | 300 kg |
| Commode Sling | Optional |
| Full-Body Sling | Optional |
| Head-Support Sling | Optional |
| Pediatric Sling | Optional |
| Bariatric Sling | Optional |
| Sling Compatibility | Subject to User Fit, Intended Task and Component Ratings |
| Section | Standard Package |
| Electric Hoist Frame | Included |
| Electric Linear Actuator | Included |
| Electrical Control Box | Included |
| Rechargeable Lithium-Ion Battery | Included |
| 24V Smart Charger | Included |
| Wired Handset | Included |
| Adjustable Base | Included |
| Spreader Bar | Included |
| Transfer Sling | Included |
| Walking Sling | Included |
| User Manual | Available |
| Section | Customization |
| Alternative Boom Length | On Request; Engineering Approval Required |
| Customized Mast Height | On Request; Engineering Approval Required |
| Modified Base Configuration | On Request; Stability Validation Required |
| Additional Sling Options | Available Separately |
| Replacement or Additional Battery | Available on Request |
| Structural Modifications | Subject to Separate Engineering Validation |
| Section | Warranty & Support |
| Frame Warranty | 12 Months |
| Motor Warranty | 3 Years |
| Electric Linear Actuator Warranty | 3 Years |
| Lithium-Ion Battery Warranty | 3 Years |
| Warranty Conditions | Applicable Written Component Warranty Terms |
| Dispatch | Typically 2–3 Working Days |
| Estimated Delivery | 4–5 Working Days After Dispatch |
| Delivery Condition | Knock-Down |
| Assembly Time | Approximately 30 Minutes |
| Virtual Installation Assistance | Available |
| After-Sales Technical Support | Available |
Bed-to-Wheelchair Transfers
Snapdragon helps trained caregivers move a suitable user from a bed to a wheelchair, or between compatible seating surfaces, using the included transfer sling.
The electric lifting mechanism reduces the need for direct manual lifting while allowing controlled raising and lowering through the wired handset.
Before each transfer, assess the user's positioning needs, sling fit, bed and wheelchair dimensions, floor clearance and available caregiver assistance.
Transfers Between Compatible Care Surfaces
Snapdragon may assist with transfers involving beds, wheelchairs and other compatible care equipment.
The adjustable base helps accommodate different equipment arrangements. However, compatibility with an individual bed, chair or commode must be assessed.
Specialized commode or head-support slings may be required for certain users and are available separately.
Floor-Level Patient Lifting
The lifting hook operates across a published approximate range of 2–7.5 ft above the floor.
This allows selected floor-level lifting applications when the user can be positioned appropriately in an approved sling.
If someone has fallen, possible injuries must be assessed before moving them.
Supported Standing Activities
The included walking sling can provide external lifting support during selected therapist-directed standing activities.
A physiotherapist should determine whether the user's head and trunk support, joint positioning and lower-limb loading are appropriate.
The hoist does not independently establish safe standing posture.
Therapist-Supervised Gait Training
Snapdragon's walking-sling configuration may support selected assisted stepping and walking exercises.
Morecare has confirmed that the current frame, boom and walking-sling configuration is intended for these applications when appropriately assessed.
The system does not independently control walking movement, balance or foot placement.
Homecare and Hospital Patient Handling
Snapdragon may support routine patient-handling requirements in homes, hospitals, nursing facilities and rehabilitation centres.
Correct training, sling selection, space planning and equipment checks are essential for use.
Realistic Functional Outcomes
Snapdragon's main purpose is to provide powered lifting assistance for patient transfers and selected supported rehabilitation activities.
It can reduce the amount of direct manual lifting required from caregivers.
It does not guarantee independent transfers, walking recovery or specific clinical improvements.
Who Is Snapdragon Suitable For?
- Adults who need significant assistance when transferring from a bed to a wheelchair or other compatible care surface.
- Users who cannot safely complete routine transfers without mechanical lifting assistance.
- Selected users requiring floor-level lifting using an approved procedure and appropriate sling.
- Individuals who may benefit from professionally supervised supported standing or gait training using the walking sling.
- Homecare or clinical environments with suitable floor space, equipment clearance and trained caregivers.
Maximum Weight and Sling Suitability
Snapdragon has a manufacturer-rated 300 kg Safe Working Load based on internal testing.
Both standard slings are rated 300 kg.
Safe selection must consider the user's body measurements, the sling size, attachment configuration, positioning requirements and the lowest-rated component.
Which Sling Should You Choose?
Transfer Sling — Included
Designed for assessed patient-transfer activities between compatible care surfaces.
Walking Sling — Included
Used for selected supported standing and gait-training exercises under professional supervision.
Commode Sling — Optional
May be suitable for certain toileting transfers after a compatibility and support assessment.
Full-Body or Head-Support Sling — Optional
Considered when the user requires a different level or arrangement of head and trunk support.
Pediatric and Bariatric Slings — Optional
Available for review according to individual measurements and rated compatibility.
Not every sling is appropriate for every activity or user.
When Another Product May Be Better
- If the person needs a dedicated sit-to-stand rehabilitation device rather than full sling-assisted lifting, a powered standing aid may be more appropriate.
- If controlled body-weight support during treadmill training is the main goal, consider a purpose-designed body-weight-support gait-training system.
- If the hoist cannot safely enter the required room or approach the bed or wheelchair, an alternative transfer solution may be necessary.
- If the user requires special positioning or a sling that cannot be safely fitted to the selected hoist, another system should be considered.
Measurements to Share Before Ordering
- User height and weight.
- Hip, trunk and other relevant body measurements.
- Head control, trunk control and general mobility limitations.
- Ability to sit, stand or bear weight.
- Intended lifting and transfer activities.
- Bed height and under-bed clearance.
- Wheelchair dimensions.
- Doorway width and turning space.
- Floor condition and available caregiver assistance.
Customization Options
- Different compatible sling sizes and designs.
- Custom mast heights and boom configurations.
- Modified adjustable-base configurations.
- Additional or replacement batteries.
- Other modifications subject to engineering review and testing.
Structural changes must not be assumed to retain the standard 300 kg rating without appropriate validation.
Before Ordering
Share the patient's requirements and room measurements with Morecare.
The team can help review sling selection, equipment clearance, standard inclusions and whether a customization is appropriate.
Confirm the final specification, price, optional accessories and delivery terms before payment.
Before Using Snapdragon
- Read the current Morecare Snapdragon User Manual and obtain practical operating training.
- Establish an individual patient-handling plan, including the correct sling, transfer procedure and number of caregivers required.
- Confirm the user's weight and the load rating of every fitted sling and lifting component.
- Check the floor, wheelchair, bed and surrounding area for suitable clearance.
- Confirm that the lift has sufficient battery charge and that the operator understands the approved emergency procedure.
Pre-Use Inspection
- Check the frame, base, mast, boom, spreader bar and sling attachment points.
- Inspect sling straps, stitching, loops and other load-bearing components for wear or damage.
- Check all castors, wheel brakes, frame connections and adjustment mechanisms.
- Verify the electrical control box, handset, battery and actuator operate normally.
- Never use a damaged sling, loose lifting connection or defective electrical component.
During Patient Transfers
- Follow the approved model-specific brake sequence for lifting, lowering and repositioning.
- Select the transfer sling according to the user's measurements and support requirements.
- Check all sling attachment points before raising the person.
- Use the wired handset for controlled lifting and lowering.
- Keep the user under direct supervision throughout the transfer.
- Raise only as much as necessary for the planned movement.
- Avoid rapid movement, swinging, sudden turns and obstacles.
- Never leave a patient suspended and unattended.
- Do not use the hoist on stairs, slopes or unstable ground.
Supported Standing and Gait Training
- Use the walking sling only when the rehabilitation professional considers the activity appropriate.
- Confirm the sling position, support requirements and planned level of assistance.
- Use the approved frame and brake configuration for the intended exercise.
- Monitor comfort, breathing, alignment and signs of fatigue or instability.
- Stop immediately if the user experiences pain, distress or poor positioning.
- Do not use the device as an independent walking aid.
Emergency Stop and Recovery
- Snapdragon includes an emergency-stop system.
- Follow Morecare's approved emergency-stop activation and reset instructions.
- Emergency lowering is not available.
- An approved assisted-recovery procedure must be understood before a person is lifted.
- If power or the lifting mechanism fails while a person is suspended, follow the documented manufacturer-specific recovery procedure and obtain the required assistance.
- Never release an actuator, loaded connection or structural locking component to improvise lowering.
Battery and Electrical Care
- Use the supplied compatible 24V smart charger.
- Follow the manufacturer's charging and battery-storage instructions.
- Keep battery terminals, controller and electrical connections dry.
- Do not use a damaged charger or electrical cable.
- Do not assume the device may be operated while charging unless the approved operating manual permits it.
Cleaning and Maintenance
- Wipe the powder-coated frame using a soft damp cloth and suitable mild cleaner.
- Clean each sling according to its material label and care instructions.
- Allow washed components to dry fully before reuse.
- Inspect lifting connections, castors, brakes, straps and electrical cables regularly.
- Replace damaged components using manufacturer-approved parts.
- Keep the actuator, battery, controller and charger protected from water and excessive moisture.
- Do not pressure-wash the hoist.
- Arrange preventive servicing and electrical/mechanical inspection as required.
Important Safety Limitation
The 300 kg Safe Working Load is manufacturer-rated from internal testing.
The 6000 N actuator rating does not independently determine the safe patient load.
The IP54 specification applies to the actuator and should not be represented as an ingress-protection rating for the entire hoist.
Shipping & Delivery
Orders are typically dispatched within 2–3 working days after confirmation.
Estimated delivery is approximately 4–5 working days after dispatch, depending on the destination and product configuration.
Customized orders may require additional preparation time.
Installation
Snapdragon is supplied in knock-down condition.
Assembly typically takes approximately 30 minutes.
Morecare provides installation videos and virtual setup guidance.
Before operating the lift with a person, check all structural connections, sling attachments and safety systems.
Warranty
The following component warranty periods are confirmed for Morecare Snapdragon
- Frame: 12 months.
- Motor and Electric Linear Actuator: 3 years.
- Lithium-Ion Battery: 3 years.
The general manufacturing-defect warranty is 12 months. Longer component-specific periods apply to the listed components according to Morecare's written warranty conditions and exclusions.
Warranty claims are subject to the applicable written policy and purchase documentation.
Returns and Transit Damage
Transit damage must be reported within 48 hours of delivery with supporting photographs or videos.
Returns, exchanges, cancellations and custom-order conditions are governed by Morecare's applicable published policy and statutory consumer rights.
Please refer to the Morecare Customer Policy Guide for details.
Technical Support
Morecare provides virtual assistance with assembly, operating guidance, troubleshooting and compatible replacement parts.
Paid repair and servicing may be available after the applicable warranty period.
Morecare Support
Phone / WhatsApp: +91 63775 09047
Website: https://morecare.in/snapdragon/
Product Showcase & Reviews
Watch clinical insights and customer experiences.
Every Choice Has a Story
Choosing the right rehabilitation equipment is about finding the right fit for your family. Read why families chose this product
FAQs related to Snapdragon – Electric Patient Lift & Transfer Hoist with Gait Training Support
Find quick answers to common questions about this product.
Snapdragon is a battery-powered electric patient lift used for assisted transfers between compatible care surfaces, selected floor-level lifting and therapist-supervised supported standing or gait activities. It provides powered lifting assistance but does not independently make a person stand or walk.
Yes, provided the transfer is appropriate for the person, the correct sling is fitted and trained caregivers follow the approved handling procedure. Snapdragon has an approximate hook-height range of 2–7.5 ft from the floor. If someone has fallen, potential injuries must be assessed before moving them.
Morecare confirms a manufacturer-rated Safe Working Load of 300 kg based on internal testing. Both the included transfer sling and walking sling are rated for 300 kg. The permissible load for any use must not exceed the lowest-rated component in the actual lifting configuration. Individual fitting and sling compatibility remain essential.
Yes. Snapdragon includes both a transfer sling and a walking sling in its standard ₹86,000 configuration. Commode, full-body, head-support, pediatric and bariatric slings are optional and subject to separate suitability assessment and pricing.
Snapdragon includes an emergency-stop function, removable lithium-ion battery, wired lifting controller and 24V smart charger. The published charging time is approximately four hours. Emergency lowering is not available, so operators must understand the approved assisted-recovery procedure before lifting a person.
Morecare confirms a 12-month frame warranty and three-year warranties for the motor, electric linear actuator and lithium-ion battery, subject to the applicable written terms. Snapdragon ships in knock-down condition with an estimated 30-minute assembly time and virtual installation support. Dispatch is typically 2–3 working days, followed by approximately 4–5 working days for delivery depending on location.