Proudly Made in India
|
PAN India Delivery
|
Free Consultation on Call
Proudly Made in India
PAN India Delivery
Free Consultation on Call
Morecare – Mobility & Rehabilitation Solutions
Lifting & Transfer Solutions

Morecare i Gait – Electric Body Weight Support Gait Trainer

₹86,000

An electric body-weight support gait trainer with overhead harness suspension and adjustable parallel bars for therapist-supervised standing, balance and walking rehabilitation.

User Height Approx. 4 ft 8 in–6 ft 5 in; fitting required
Maximum User Weight 150 kg in standard configuration
Harness Fit Medium 60–100 kg; Large 90–150 kg
Training Environment Supervised indoor overground or treadmill sessions
Select Variant
Quantity
Ready to DispatchIn Stock
EMI
EMI Available on eligible cards
Visa Mastercard RuPay UPI
Powered by
Pan-India
Delivery
Warranty
Support
Return
Eligibility
Lifetime
Support

Product Information

Everything you need to know about this product.

Electric Body-Weight Support for Standing and Walking Practice

For some rehabilitation users, staying upright and practising steps is difficult even with conventional walkers or parallel bars. Reduced leg strength, impaired balance or difficulty controlling posture can make walking practice demanding for the user and therapist.

The Morecare i-Gait brings together an overhead electric suspension system, fitted body harness and adjustable parallel bars to assist selected adolescents and adults during supervised standing and gait-training sessions.

How i-Gait Helps

  • Electric Harness Positioning: The overhead motorized lifting system raises and positions the user through an appropriately fitted body harness. The therapist uses a wired handset to adjust the supported position.
  • Additional Body Support: Harness suspension provides assistance during standing, stepping and weight-shifting activities, allowing therapists to plan exercise around the user's remaining abilities.
  • Adjustable Parallel Bars: Stainless-steel handrails adjust in height and width to support individual body dimensions and therapy tasks.
  • Two Harness Sizes Included: Medium (60–100 kg) and Large (90–150 kg) harnesses are supplied. Correct fit depends on body measurements, not weight alone.
  • Overground and Treadmill Training: The system is intended for indoor gait practice on suitable level surfaces and can be configured with a compatible treadmill after a clearance and safety assessment. The treadmill is not included as standard.
  • Mains-Powered Operation: The standard i-Gait operates on 220V AC mains power. Battery backup is available separately at an additional cost.

A Rehabilitation System, Not a Transfer Hoist

i-Gait supports therapist-guided standing and walking activities. It is not a general-purpose hoist for bed-to-wheelchair transfers or an unattended walking aid.

Its electric drive adjusts the suspension height; it does not measure body-weight unloading or provide a selectable percentage such as 20%, 30% or 50%. Support is determined through the user's condition, position, harness arrangement and rehabilitation assessment.

The standard maximum user weight is 150 kg. The separately published 300 kg structural frame rating must not be interpreted as the permitted weight of a person using the complete harness-and-lift system.

The user's weight-bearing ability, joint movement, postural control, harness suitability, floor space and treatment goals should be reviewed by a qualified rehabilitation professional before use.

Section General Information
Product Name Morecare i-Gait
Model i-Gait
Product Type Electric Body-Weight Support Gait Trainer
Recommended Users Adolescents and Adults; Individual Assessment Required
Recommended User Height Approximately 4 ft 8 in–6 ft 5 in (140–195 cm)
Maximum Standard User Weight 150 kg
Published Structural Frame Capacity 300 kg; Not the Maximum Permitted User Weight
Primary Applications Supported Standing, Balance and Gait Training
Recommended Setting Supervised Indoor Rehabilitation
Country of Origin India
Section Frame & Construction
Frame Material Heavy-Duty Mild Steel
Handrail Material Stainless Steel
Frame Configuration Knock-Down Construction
Foldable Yes; follow product-specific folding and assembly instructions
Parallel Bars Height and Width Adjustable
Assembly Required
Section Electric Suspension System
Suspension Type Overhead Electric Lift with Body Harness
Powered Function Electric Raising and Positioning of Suspension Height
Control Wired Handheld Remote
Body-Weight Assistance Yes; Amount Depends on Fit and Positioning
Measured Unloading Percentage Not Available
Percentage-Based Unloading Control Not Available
Power Supply 220V AC
Battery Backup (Standard) Not Included
Optional Battery Backup Available at Additional Cost
Power Failure Behaviour (Without Optional Battery) Suspension Holds Position; Electric Raising and Lowering Unavailable Until Mains Power Returns
Emergency Recovery Follow the Approved Written Recovery Procedure
Section Harness & Positioning
Body Support Overhead Suspension with Fitted Body Harness
Included Harnesses Medium and Large; Both Included
Medium Harness User Range 60–100 kg
Large Harness User Range 90–150 kg
Harness Selection Based on Weight, Body Dimensions and Therapist Assessment
Maximum Standard User Weight 150 kg
Custom Harness Sizes Available on Request
Pediatric Configuration Available on Request; Separately Assessed
Bariatric Configuration Available on Request; Capacity Requires Separate Confirmation
Section Therapy Applications
Supported Standing Yes; Professionally Supervised
Overground Walking Practice Yes; Suitable Indoor Level Surfaces
Treadmill-Assisted Gait Training Compatible After Equipment Assessment
Balance and Weight-Shifting Activities Yes; Therapist Guided
Parallel Bar Height Adjustment Provided
Parallel Bar Width Adjustment Provided
Exact Percentage Body-Weight Unloading Not Measured or Set by This System
Section Wheels & Safety
Caster Type Medical-Grade Swivel Castors
Caster Diameter 5 Inches
Caster Brakes All Wheels Lockable
Wheel Lock Sequence Follow Approved Procedure for Each Training Mode
Professional Supervision Required
Unattended Suspension or Training Not Permitted
General-Purpose Patient Transfer Hoist No
Power Interruption (Standard Configuration) Holds Current Position; Electric Raising and Lowering Unavailable Without Mains Power
Section Customization & Configuration
Standard Configuration Adolescent and Adult Body-Weight Support Training
Pediatric Configuration Available on Request
Bariatric Configuration Custom Option; Separate User Capacity Confirmation Required
Custom Frame Dimensions Available on Request
Custom Harness Sizes Available on Request
Parallel Bar Dimensions Adjustable; Custom Options on Request
Custom Colour Available on Request
Additional Therapy Accessories Subject to Technical Feasibility
Battery Backup Optional Paid Add-On; Not Included in Standard Price
Section In the Box
Main Support Frame Included
Electric Suspension Assembly Included
Wired Handheld Controller Included
Adjustable Parallel Bars Included
Medium Harness Included
Large Harness Included
Lockable Castors Included
Battery Backup Not Included; Optional at Additional Cost
Treadmill Not Included
Installation Guidance Available
Section Shipping & Warranty
Assembly Configuration Knock-Down
Typical Assembly Time Approximately 30 Minutes
General Warranty 12 Months Against Qualifying Manufacturing Defects
Technical and Spare-Part Support Available Through Morecare

Neurological Rehabilitation

Selected people recovering from stroke or acquired neurological injury may need additional support to practise standing and stepping. i-Gait enables a therapist to position the user in a body harness and guide standing, balance and gait tasks according to an individual rehabilitation plan.

Stroke and Hemiplegia Gait Practice

The body-weight support harness and adjustable parallel bars provide an environment for supervised weight transfer, step initiation and repeated walking practice.

Use depends on the person's postural control, lower-limb capacity and therapy goals.

Orthopaedic and Postoperative Rehabilitation

For selected patients cleared for weight-bearing activity, i-Gait may assist therapist-led standing and mobility practice.

It does not quantify the force being borne by the legs, so it must not be used as a substitute for measured load control when a precise weight-bearing restriction applies.

Balance and Weight-Shifting Exercises

The fitted body harness can provide extra support while therapists work on upright positioning, lateral weight transfer and selected balance activities.

Support requirements must be reassessed during each stage of training.

Standing Tolerance

For suitable users, therapist-controlled suspension can help facilitate periods of supported upright practice.

Session duration depends on medical stability, comfort and the rehabilitation plan.

Overground Gait Training

On suitable level indoor floors, i-Gait can support supervised stepping practice with the parallel bars and suspension system.

The appropriate frame movement and brake procedure must follow the specific training setup and approved instructions.

Treadmill-Assisted Walking

i-Gait can be used with a suitably compatible treadmill where dimensions, stability, belt access, clearance and supervision have been assessed.

The treadmill is a separate device and is not included in the standard package.

Practical Purpose and Outcomes

The system is designed to make participation in supported standing, weight shifting and gait training possible for selected rehabilitation users.

Gains in balance, walking ability or independence cannot be guaranteed.

Who May Be Suitable

  • Adolescents and adults who need overhead harness assistance to participate in therapist-supervised standing or gait training.
  • Users up to 150 kg who can be correctly fitted within the standard medium or large harness and frame-height range.
  • Rehabilitation centres and suitable home programmes with qualified supervision and sufficient stable indoor space.
  • Patients who need additional support beyond ordinary walking frames or parallel bars, as established by a therapist.

When Another Solution May Be Better

  • When the main task is moving a person from bed to wheelchair, consider a dedicated patient-transfer hoist rather than i-Gait.
  • When the clinician requires precise, measured unloading percentages or strict partial-weight-bearing limits, use equipment with an appropriate force measurement and control system.
  • Users above 150 kg cannot be approved solely on the frame's 300 kg structural rating; customized systems require a separate complete-system rating.
  • Where adequate head/trunk control, medical stability, harness fit or supervision cannot be established, a different positioning or gait-training system may be needed.
  • In locations without adequate overhead, doorway, treadmill or turning clearance, the standard system may not be appropriate.

Information to Share Before Ordering

User Measurements

  • Age, height and body weight.
  • Waist, hip and trunk measurements.
  • Medical condition and rehabilitation goals.
  • Current standing and stepping abilities.
  • Range of motion, spasticity or contractures where relevant.
  • Recommended harness support.

Therapy Requirements

  • Supported standing, overground gait training, treadmill training or a combination.
  • Expected session frequency.
  • Whether precise unloading measurement is clinically required.

Facility Requirements

  • Room dimensions and clear overhead height.
  • Doorway width and floor type.
  • Available 220V AC electrical supply.
  • Treadmill make, model and dimensions, where applicable.
  • Available space for therapist assistance and movement.

Fit and Rating Guidance

Published harness ranges are Medium 60–100 kg and Large 90–150 kg; both are supplied as standard.

The overlapping weight range does not eliminate the need to measure the user's body.

Confirm any alternative pediatric, bariatric or custom configuration and its approved capacity in writing before purchase.

Available Customization

  • Pediatric or customized harness sizes.
  • Custom frame dimensions.
  • Parallel bar height and width configuration.
  • Bariatric configurations, subject to separate capacity approval.
  • Alternative colour finishes.
  • Additional accessories subject to technical feasibility.
  • Optional battery backup at additional cost.

Key Limitations

The standard complete-system user limit is 150 kg.

The separate 300 kg structural frame capacity does not increase it.

The lifting mechanism does not display or control a measured body-weight unloading percentage.

Qualified professional supervision is required.

Available Configuration Options

  • Electric harness suspension height adjusted through the included wired hand controller.
  • Stainless-steel parallel bars with height and width adjustment.
  • Medium (60–100 kg) and Large (90–150 kg) harnesses included as standard.
  • Pediatric harnesses, bariatric designs, custom frame dimensions, alternative sling sizes, colour finishes or additional therapy accessories may be discussed; compatibility, pricing and approved load rating must be confirmed before ordering.
  • Battery backup is optional at additional cost and is not included in the standard ₹86,000 configuration.
  • Confirm the battery option, power-failure operation, charging and backup runtime before ordering.

Before Every Training Session

  • Obtain a qualified assessment of the user's medical stability, body dimensions, functional abilities and planned gait-training task.
  • Check that the user's weight is within the 150 kg standard rating and the selected harness's permissible range.
  • Inspect the harness stitching, buckles, suspension straps, hooks and attachment points for damage or wear.
  • Check all frame fasteners, handrail adjustments, brakes, castors and electrical connections.
  • Confirm the operating surface is level, the training area is clear and sufficient caregiver or therapist space is available.
  • Test the control system before placing the user's weight into the harness.
  • Establish the manufacturer's approved recovery and assisted-lowering plan for a power or actuator failure before lifting a user.

During Supported Standing and Walking

  • Qualified therapist or trained caregiver supervision is required throughout.
  • Never leave a user suspended or unattended.
  • Fit the body harness correctly and raise or lower using only the intended electric controller.
  • Adjust handrails for the user's dimensions and secure the locking hardware.
  • Follow the approved castor brake and frame movement procedure for stationary standing, overground training and treadmill sessions; these phases can require different settings.
  • Keep clothing, limbs, cables and loose equipment away from moving mechanical parts and treadmill belts.
  • Stop the activity if distress, pain, instability, sling shifting, abnormal noise or electrical faults occur.
  • Do not use i-Gait for general bed-to-wheelchair transfers or unrelated patient lifting.

Power Failure and Emergency Planning

The standard i-Gait operates on 220V AC mains power and does not include battery backup.

When mains power fails, electric raising and lowering are unavailable on the standard unit.

The published product specifications state that the suspension remains in its current position during a power cut.

Battery backup can be supplied as an additional-cost option, but its operating capability and runtime must be confirmed for the actual configured unit.

Do not assume a manual emergency-lowering function unless it is specified in the approved instructions.

Operators must follow the written, model-specific approved recovery procedure supplied with the unit.

Establish a safe assisted-recovery plan before suspending a user and never leave a person unattended in the harness.

Cleaning, Care and Maintenance

  • Disconnect mains power before cleaning or servicing.
  • Wipe the painted frame and stainless-steel handrails with a soft damp cloth and mild cleaner.
  • Clean the body harnesses according to their care labels; dry fully before reuse.
  • Keep the handset, actuator, control unit and connectors dry.
  • Do not pressure-wash electrical parts.
  • Inspect sling materials, fasteners, suspension points, cable routing, brakes and moving assemblies regularly.
  • Remove debris from castors and verify that all locks work correctly.
  • Do not use equipment that is damaged, worn or functioning abnormally.
  • Contact Morecare for approved servicing and replacement parts.

Storage and Relocation

Store clean and dry indoors.

Follow the approved knock-down and reassembly procedure.

Verify all locks, fasteners, electrical connections and suspension attachments before the next session.

Shipping & Dispatch

  • Order Processing – Approximately 48–72 working hours after payment confirmation.
  • Dispatch – Within an additional 48–72 working hours, subject to availability.
  • Delivery – Approximately 5–7 working days after dispatch.
  • Shipping Charges – Included in the product price for serviceable locations across India.
  • Customized Orders – Dispatch timelines confirmed before order placement.

Installation & Setup

  • Supplied in knock-down condition for transportation.
  • Assembly takes approximately 30 minutes.
  • Installation video and free virtual setup guidance are available.

Returns, Replacement & Refunds

  • Returns, replacements, and refunds are subject to Morecare's published policies.
  • Report transit damage within 48 hours of delivery with supporting photographs or videos.
  • Customized orders are subject to specific return conditions.

Warranty

  • 12-month warranty against manufacturing defects.
  • Normal wear, accidental damage, misuse, overloading, and unauthorized modifications are excluded.
  • A valid purchase invoice is required for warranty claims.

After-Sales Support

  • Assistance with installation, adjustments, troubleshooting, and repairs.
  • Replacement parts available subject to stock.
  • Support Hours – Monday to Saturday, 11 AM–6 PM.
  • Official Support – +91 63775 09047.

Product Showcase & Reviews

Watch clinical insights and customer experiences.

FAQs related to i Gait – Electric Body Weight Support Gait Trainer

Find quick answers to common questions about this product.

It is intended for selected adolescents and adults who need additional harness support during supervised standing, balance and walking rehabilitation. The recommended height range is approximately 4 ft 8 in–6 ft 5 in, and the maximum standard user weight is 150 kg. A therapist should confirm medical and functional suitability before use.

The overhead motorized suspension raises and positions the fitted harness using a wired hand controller. It provides body-weight assistance but does not measure, display or automatically set a percentage of weight unloading. It should not replace equipment that measures precise weight-bearing limits when those are required.

The standard maximum user weight is 150 kg. The separate 300 kg figure refers to structural frame capacity only, not approval for a 300 kg user or harness suspension. A larger customized configuration requires its own approved complete-system and harness ratings.

Medium and Large harnesses are included. The medium weight range is 60–100 kg and the large range is 90–150 kg. Correct choice also depends on user dimensions, posture, suspension points and therapist assessment. Custom harness sizes may be requested.

Yes. i-Gait supports indoor overground gait training and is compatible with treadmill-assisted rehabilitation. Before treadmill use, confirm machine dimensions, belt access, clearances, frame stability, brake setup and professional supervision. A treadmill is not included in the standard package.

No. The standard i-Gait operates on 220V AC mains power and does not include battery backup. Battery backup is available as an optional paid add-on. Without this option, electric lifting and lowering are unavailable during a mains power failure. The published specification states that the suspension holds its position. Operators must follow the approved assisted-recovery procedure. Installation guidance and a 12-month manufacturing-defect warranty are provided.

Need Help Finding the
Right Solution?

Our rehabilitation experts are here to help you choose the right product or create a customized solution tailored to your needs.

Your Cart

Category

Product Title

₹0

Description

Select Variant
View Full Details
Item added to cart!
Home Kids Adults
Morecare i Gait – Electric Body Weight Support Gait Trainer ₹86,000