Proudly Made in India
|
PAN India Delivery
|
Free Consultation on Call
Proudly Made in India
PAN India Delivery
Free Consultation on Call
Morecare – Mobility & Rehabilitation Solutions
Seating & Standing Solutions

Morecare Victoria – Adjustable Adult Supported Standing Frame

₹20,000

A manually adjustable adult standing frame with chest, back, pelvic and lower-limb positioning supports and an adjustable activity table, designed for therapist-prescribed supported standing and daily activities.

Recommended User Height Approximately 5–6 ft; fitting required
Maximum User Weight 120 kg published; validation pending
Support Needs Adults requiring chest, back, pelvic and leg positioning
Standing Suitability Supervised static standing; assisted transfer required
Select Variant
Quantity
Ready to DispatchIn Stock
EMI
EMI Available on eligible cards
Visa Mastercard RuPay UPI
Powered by
Pan-India
Delivery
Warranty
Support
Return
Eligibility
Lifetime
Support

Product Information

Everything you need to know about this product.

Supported Standing for Adults Who Need More Than a Conventional Standing Aid

For adults recovering from a neurological injury or living with reduced muscle control, maintaining an upright standing position may require extensive assistance. The challenge is not simply getting upright—it is establishing a well-supported position that can be maintained safely while taking part in prescribed rehabilitation or everyday tasks.

The Morecare Victoria is a manually adjustable adult supported-standing frame with an integrated foot platform, adjustable chest and back pads, pelvic positioning components, thigh and calf straps, knee support and a height-adjustable activity table. It provides multiple points of external support so an appropriately assessed user can take part in supervised static-standing sessions.

How Victoria Helps Solve the Standing Challenge

  • Multi-Point Body Positioning: Adjustable chest, back, pelvic and lower-limb supports help a therapist configure the frame around the person's positioning needs instead of relying on an unsupported upright stance.
  • Adjustable Standing Table: The activity table adjusts manually from approximately 99–119 cm (39–46.9 inches). It can provide a surface for selected hand activities, communication, reading or therapist-guided tasks while upright.
  • Anterior and Posterior Trunk Support: Padded chest and back supports can be positioned to help maintain the person's assessed trunk alignment without excessive compression.
  • Lower-Limb Positioning: Thigh straps, adjustable knee positioning, calf straps and the integrated foot platform help establish a supported lower-body arrangement when clinically permitted.
  • Manually Adjustable Construction: Table height and body-positioning adjustments do not depend on a powered lifting system. All adjustment points must be secured before use.
  • Individual Fitting: The published recommended user-height range is approximately 5–6 ft, with an overall frame footprint of about 85 cm long × 67 cm wide. Proper fit depends on the person's body measurements and support needs.

Who May Benefit From Victoria?

Victoria may be considered for selected adults who cannot maintain standing safely without external support and have an appropriate professionally prescribed standing programme. Depending on individual assessment, potential users may include adults with stroke-related weakness, spinal cord injury, acquired brain injury or other neurological and mobility conditions.

The current product listing states a 120 kg maximum user weight, but explicitly identifies load/stability verification as pending. This should remain a provisional published specification until Morecare confirms testing for the complete assembled frame.

Standing with Purpose

The adjustable activity table creates opportunities to pair prescribed standing with selected reaching, communication, reading, handling objects or supervised exercises. Its height adjustment helps bring the activity surface into a more suitable working position. Whether a particular task is possible depends on arm control, positioning and the rehabilitation programme.

Important Product Limitations

Victoria is a stationary supported-standing device—not a powered sit-to-stand lift, walking trainer, standing wheelchair or general-purpose transfer hoist. It does not independently raise or transfer a person from a wheelchair. Users must be transferred and positioned using an individually assessed method with the necessary trained assistance.

Victoria does not measure or regulate weight-bearing forces. Access to supported standing is its immediate purpose; improvements in walking, bone density, strength, balance or independence are not guaranteed.

Section General Information
Product Name Morecare Victoria
Model Victoria
Product Category Adult Seating & Standing Solutions
Product Type Manually Adjustable Adult Supported Standing Frame
Recommended User Group Adults requiring external support for static standing
Published User Height Range Approximately 5–6 ft; individual fitting required
Published Maximum User Weight 120 kg; manufacturer load/stability validation pending
Primary Function Therapist-Prescribed Supported Static Standing
Powered Standing No
Walking Function No
Patient Transfer / Hoist Function No
Country of Origin India
Recommended Environments Suitable Homes, Physiotherapy Clinics and Rehabilitation Centres
Section Frame & Dimensions
Frame Construction Metal Tubular Frame; specific metal grade not published
Overall Length Approximately 85 cm / 33.5 in
Overall Width Approximately 67 cm / 26.4 in
Overall Height Not Published
Product Weight 25 kg, as published
Foot Platform Integrated Standing / Foot-Positioning Platform
Standing Orientation Static Upright Supported Positioning
Manual Adjustment Yes
Foldable Not Specified in Uploaded Product Record
Base Wheels / Castors Configuration Not Confirmed
Floor Surface Firm, Level, Stable Surface
Section Standing Table
Activity Table Integrated; Height Adjustable
Standing Table Height 99–119 cm (39–46.9 in)
Table Adjustment Manual
Table Tilt Not Stated
Table Safe Load Not Published; do not use for patient support or lifting
Forearm Support Listed as available; exact supplied configuration unconfirmed
Section Body Supports
Chest Support Adjustable Padded Anterior Trunk Support
Back Support Adjustable Padded Posterior Trunk Support
Pelvic Support Adjustable Support
Thigh Support Adjustable Straps
Knee Support Adjustable Positioning Support
Calf Support Adjustable Straps
Foot Positioning Integrated Foot Platform
Head Support Not Specified in Standard Configuration
Harness / Strap Sizing Assess User Measurements; Exact Range Not Published
Section Transfer & Safety
Standing Support External Positioning Support; not independent balance
Wheelchair User Suitability Possible for Selected Users After Professional Assessment
Independent Wheelchair-to-Frame Transfer Not Established; Individual Assisted Transfer Plan Required
Powered Sit-to-Stand Not Provided
Body-Weight Unloading Measurement Not Provided
Weight-Bearing Programme Therapist Prescribed
Use While Unattended Not Permitted
Maximum User Weight 120 kg Published; Testing Verification Pending
Brake Procedure Only if applicable to fitted base; configuration requires confirmation
Inspection Supports, fasteners, locks, straps and frame before every use
Section Adjustments & Customization
Chest Support Position Adjustable
Back Support Position Adjustable
Pelvic Support Position Adjustable
Thigh Strap Fit Adjustable
Knee Position Adjustable
Calf Strap Fit Adjustable
Standing Table Height Adjustable from 99–119 cm
Forearm Support Configuration Available / Exact Inclusion to Confirm
Nonstandard Support Arrangements Discuss With Morecare; engineering and fitting review required
User-Height Alteration Only if specifically approved; not standard
Structural Changes Require separate stability and load validation
Section Standard Configuration / Inclusions
Adult Standing Frame Described as standard
Integrated Standing Foot Platform Included in described configuration
Height-Adjustable Activity Table Included in described configuration
Adjustable Chest Support Described in current product record
Adjustable Back Support Described in current product record
Adjustable Pelvic Support Described in current product record
Thigh Straps Described in current product record
Knee Support Described in current product record
Calf Straps Described in current product record
Forearm Support Available; confirm whether included in price
Wheels / Castors Not confirmed for supplied model
Section Shipping, Warranty & Support
Published Price ₹20,000
Dispatch Typically 2–3 Working Days after order confirmation
Estimated Delivery 4–5 Working Days after dispatch; location/configuration dependent
Delivery Condition Knock-Down (per existing listing)
Approximate Assembly Time 30 Minutes
Virtual Setup Assistance Available
Warranty 12 Months Against Manufacturing Defects Under Current Written Terms
Transit Damage Reporting Within 48 Hours with Photos/Videos (per current record)
After-Sales Service Setup Guidance, Troubleshooting, Replacement Parts and Servicing

Supported Standing for Adults with Reduced Standing Control

Victoria offers adjustable external body support for selected adults who cannot maintain an upright position safely without assistance. A qualified healthcare professional must determine whether standing is appropriate, how the user is transferred, and how long each session should last.

Postural Positioning During Rehabilitation

Adjustable chest, back, pelvic and lower-limb components can be configured around the person's body measurements, joint range and posture.

The purpose is to provide a supported position—not to claim independent balance or correct fixed deformities.

Stroke and Neurological Rehabilitation

For some adults recovering from stroke or acquired brain injury, or living with other neurological conditions, Victoria may be incorporated into a prescribed standing programme after assessment of cardiovascular tolerance, joint restrictions, bone health and support requirements.

Selected Spinal Cord Injury Programmes

Some people living with spinal cord injury may be considered for supported static standing.

Professional screening and an appropriate transfer/positioning plan are particularly important, including relevant precautions for skin integrity and standing tolerance.

Therapist-Prescribed Lower-Limb Weight Bearing

When weight bearing is clinically permitted, a therapist may use Victoria during supervised upright loading activities.

The device does not display a percentage of supported body weight and does not automatically regulate loading.

Upper-Limb Activity and Participation

The adjustable 99–119 cm standing table can provide an activity surface for selected reaching, object handling, reading, communication tools and exercise tasks while the user is adequately supported.

Table height must be fitted without compromising posture or breathing.

Supervised Home and Clinical Use

Victoria may suit therapy facilities or prepared home environments where there is adequate floor space, a suitable transfer method and trained caregiver assistance.

Suitability cannot be assumed simply because the frame is described as appropriate for wheelchair users.

Realistic Outcomes

Victoria helps selected individuals access supported upright positioning and participate in appropriate activities.

Independent standing, walking recovery, stronger bones, better circulation and prevention of contractures are not guaranteed outcomes.

Who May Be Suitable?

✓ Adults who require adjustable external trunk, pelvic and lower-limb support to participate in a prescribed static-standing programme.

✓ Individuals approximately 5–6 ft tall whose actual body measurements can be accommodated by the frame and its positioning supports.

✓ Selected people after stroke, spinal cord injury, acquired brain injury or other neurological conditions, when a qualified rehabilitation professional approves supported standing.

✓ Selected wheelchair users only when safe transfer into and out of Victoria can be achieved using an individually assessed method. Victoria itself does not lift or transfer the person.

✓ Care settings with a firm, level floor, sufficient working space and the required trained caregiver assistance.

Maximum Weight and Fit

The current Victoria product record publishes 120 kg as the maximum user weight, but marks structural load and stability verification as pending. This must not be treated as a validated load rating until approved testing is confirmed.

The published user-height range of 5–6 ft is a selection guide, not a guarantee of fit.

Adjustability must be checked against trunk dimensions, pelvic width, leg length, range of movement and required support placement.

When Victoria May Not Be the Right Solution

  • The person requires powered lifting from sitting into standing or an electric sit-to-stand transfer aid; Victoria has no powered raising function.
  • The main goal is supported stepping or walking; Victoria is a stationary standing frame rather than a gait trainer.
  • The user requires a lying-to-standing change of angle, tilt or recline; the current Victoria record does not describe these capabilities.
  • The user cannot be positioned safely because of bone/joint restrictions, postural asymmetry, poor standing tolerance or a transfer requirement that the care team cannot meet.
  • The intended environment lacks sufficient access, stable flooring or trained supervision.

Standard Adjustable Positioning Components

✓ Padded adjustable anterior chest support.

✓ Adjustable padded back support for posterior trunk positioning.

✓ Adjustable pelvic support.

✓ Adjustable thigh straps, knee support and calf straps.

✓ Integrated foot-positioning platform.

✓ Manually adjustable activity table, 99–119 cm high.

The existing product record also lists forearm support as available, but does not clearly confirm whether it is included in the ₹20,000 standard package.

Measurements and Information to Share Before Ordering

  • User age, height, current weight and relevant body measurements (pelvic width, trunk length, leg lengths and foot dimensions).
  • Current ability to sit, participate in transfers, bear weight and tolerate upright standing.
  • Head/trunk control and hip, knee or ankle movement restrictions.
  • Relevant bone, joint, cardiovascular or skin-pressure precautions and therapist instructions.
  • Present wheelchair type and the agreed caregiver-assisted transfer method.
  • Available room space, doorway width, flooring and location of other care equipment.
  • Need for forearm support or other additional positioning components.

Customization and Configuration Review

Morecare can review the user's measurements and available support positions and discuss possible non-standard adjustments.

Additional brackets, support dimensions or structural alterations must be assessed for stability, component compatibility and safe loading before approval.

Do not assume all requested alterations are available or included in the standard price.

Before You Order

Confirm the user's fit and rehabilitation programme, the final included support set, whether forearm supports are supplied, the approved load rating, any customized dimensions, delivery and the safe transfer arrangement with Morecare.

The product should be selected for supported standing—not as a substitute for a wheelchair lift or independent transfer device.

Before the First Standing Session

  • Arrange a standing and transfer assessment with the treating physiotherapist or other qualified professional. Review safe weight bearing, bone and joint precautions, skin pressure, postural alignment and cardiovascular tolerance.
  • Confirm the user's actual measurements fit the available chest, back, pelvic and lower-limb supports and table position. The website's 120 kg maximum user weight remains pending complete-system validation.
  • Read the current product instructions and establish an assisted-transfer method and required number of caregivers; Victoria does not power a transfer from a wheelchair or chair.
  • Inspect the frame and confirm all supplied components are fitted correctly. Place it on a firm, stable and level floor. If the delivered base has castors and brakes, follow its approved locking procedure.

Pre-Use Checks

  • Inspect tubular frame members, welds, adjustment knobs, locking pins, mounting brackets, straps, buckles, standing platform and table fixings.
  • Check chest, back, pelvic, thigh, knee and calf supports for correct placement and securely fastened adjustments.
  • Remove the device from use if any part is unstable, cracked, excessively worn, bent or loose. Do not use an unverified or damaged configuration.

Safe Transfer and Positioning

  • Use the individual care plan and trained caregiver assistance to position the person. Victoria does not lift or independently transfer a wheelchair user.
  • Never use the activity table, chest pad, support straps or frame projections as lifting handles for the user.
  • Position the feet on the integrated platform and adjust the support components to the person's prescribed alignment, avoiding excessive compression, skin pressure, restricted breathing or undesired joint loading.
  • Secure all adjustment mechanisms before the standing session begins.

During Supported Standing

  • Maintain appropriate continuous supervision. Follow the prescribed standing duration, support configuration and rest periods.
  • Observe breathing, comfort, head/trunk posture, skin contact, dizziness, fatigue, pain and signs of reduced standing tolerance.
  • Stop the activity immediately for faintness, pain, pressure concerns, breathing difficulty, distress, instability or a change in the user's condition.
  • Use the manually adjustable table only for suitable supervised tasks. The table is not intended for lifting or for supporting the user's full body weight.
  • Do not use Victoria for walking, transport or unsupervised standing.

Cleaning and Routine Maintenance

  • Clean the metal frame and compatible surfaces using a soft damp cloth and mild detergent. Dry thoroughly.
  • Follow material-specific care instructions for pads, straps and upholstery. Avoid bleach, harsh solvents, abrasive cleaning and excessive moisture at frame joints.
  • Regularly inspect structural joints, brackets, table adjustment, straps, buckles, the foot platform and any fitted wheels or brakes.
  • Stop use if any structural, positioning or locking component is damaged or no longer functions correctly. Arrange approved maintenance or replacement parts through Morecare.

Storage and Additional Safety Limits

  • Store indoors on stable, level flooring in a clean dry environment. Never move or adjust the frame as if it were a wheelchair while occupied.
  • Any nonstandard support or structural modification requires technical assessment and safety approval before use.
  • The published 12-month warranty concerns manufacturing defects under written terms; the source does not provide a separate validated expected product service-life rating.

Shipping & Dispatch

Morecare Victoria is available for delivery across India.

The existing product listing states typical dispatch within 2–3 working days and estimated delivery within 4–5 working days after dispatch, depending on destination and order configuration.

Confirm the delivery schedule before placing an order.

Assembly & Installation

The existing listing describes Victoria as supplied in knock-down condition, with approximately 30 minutes required for assembly.

Setup instructions, video guidance and virtual installation support are available.

Before first use, the assembled frame must be checked for stability, correct component installation and secure locking of all adjustments.

Warranty

The existing product listing specifies a 12-month warranty against manufacturing defects under normal use.

Warranty coverage is subject to the applicable Morecare warranty terms.

Normal wear, accidental damage, misuse and unauthorized modifications are excluded under the published terms.

Transit Damage & Returns

Inspect the shipment upon delivery.

The existing return terms request transit-damage reporting within 48 hours, supported by photographs or videos.

Other return, exchange, cancellation and customization conditions are governed by Morecare's published policies.

After-Sales Support

Morecare provides virtual setup assistance, adjustment guidance, troubleshooting support and access to replacement parts and servicing.

For assistance, contact Morecare through the official website.

https://morecare.in/victoria/

Product Showcase & Reviews

Watch clinical insights and customer experiences.

FAQs related to Victoria – Adjustable Adult Supported Standing Frame

Find quick answers to common questions about this product.

Victoria is a manually adjustable adult supported-standing frame for selected people who require chest, back, pelvic and lower-limb positioning support to participate in a supervised standing programme. The published height range is approximately 5–6 ft. A healthcare professional must assess safe standing, body fit and transfer requirements.

The current product page lists a maximum user weight of 120 kg, but explicitly states that structural load and stability verification are pending. It publishes an approximately 85 × 67 cm footprint, 25 kg equipment weight and a 5–6 ft recommended user-height range. The figures do not guarantee safe fit or independent use.

Victoria does not independently lift or transfer a person from a wheelchair. Some wheelchair users may be suitable for supported standing in Victoria if their clinician approves it and the care team can perform a safe, individually assessed transfer. Do not treat wheelchair suitability as a claim of independent transfer.

The published configuration describes adjustable padded chest and back supports, pelvic support, thigh and calf straps, knee support and an integrated standing platform. Forearm support is listed as available, but the product record does not confirm whether it comes in the standard ₹20,000 package; verify the exact order inclusions.

Victoria's activity table adjusts manually between approximately 99 and 119 cm, providing a surface for suitable supervised upper-limb and daily activities. Victoria is a static standing device; it does not provide powered sit-to-stand motion, walking support or motorized gait training.

The current listing states typical dispatch within 2–3 working days and estimated delivery 4–5 working days after dispatch, depending on destination and configuration. It is described as knock-down with around 30 minutes for assembly. The warranty is 12 months against manufacturing defects under applicable terms, and virtual installation guidance and after-sales help are available.

Need Help Finding the
Right Solution?

Our rehabilitation experts are here to help you choose the right product or create a customized solution tailored to your needs.

Your Cart

Category

Product Title

₹0

Description

Select Variant
View Full Details
Item added to cart!
Home Kids Adults
Morecare Victoria – Adjustable Adult Supported Standing Frame ₹20,000