Morecare Iris - Electric Tilt Table with Reclining Backrest
A dual-function electric rehabilitation tilt table with independently adjustable backrest and whole-table tilt for supported lying, reclining and gradual upright standing.





Delivery
Support
Eligibility
Support
Product Information
Everything you need to know about this product.
The Morecare Iris Electric Tilt Table with Reclining Backrest is a dual-function rehabilitation table designed for individuals who require assisted positioning, supported reclining, and gradual upright standing therapy. By combining an electrically adjustable backrest with a whole-table tilting mechanism, Iris allows users to transition between horizontal lying, raised-backrest positioning, and supported upright standing within a single rehabilitation system.
Unlike conventional tilt tables that primarily provide whole-body tilting, the Morecare Iris features two independently controlled electric positioning functions. The backrest adjusts from 0° to 85°, while the complete table tilts from 0° to 90°. Both functions operate through a wired handset, allowing caregivers and rehabilitation professionals to make controlled adjustments according to individual positioning requirements.
Why Choose the Morecare Iris?
Individuals undergoing neurological rehabilitation, prolonged bed rest, or standing tolerance training may require different levels of support during therapy. The Morecare Iris provides a practical solution by combining reclining and supported standing functions in one rehabilitation device.
Its 3-inch cushioned surface provides comfort during positioning sessions, while the chest, pelvic, and leg straps help maintain body alignment during tilting. The fixed footplate provides lower-limb support during upright positioning, and collapsible side rails allow caregivers to access the user for assisted transfers and strap adjustments.
The wired handset uses a press-and-hold control system, meaning movement stops when the button is released. This allows therapists to pause adjustments at intermediate angles while observing the user's comfort and tolerance.
Iris is supplied fully assembled and operates through mains electricity, making it suitable for hospitals, rehabilitation centres, physiotherapy clinics, and appropriately supervised home rehabilitation programmes.
Key Features
Dual-function electric rehabilitation tilt table with independently adjustable backrest and whole-table tilt.
Electric backrest adjustment from 0° to 85° for supported reclining and raised upper-body positioning.
Whole-table electric tilt from 0° to 90° for gradual upright positioning and supported standing.
Wired handset with press-and-hold operation for controlled adjustments.
3-inch cushioned surface for comfort during rehabilitation sessions.
Chest, pelvic, and leg positioning straps for supported tilting.
Fixed footplate for lower-limb support during upright standing.
Collapsible side rails for caregiver access and assisted transfers.
Four castor wheels, each equipped with an individual brake.
Maximum user weight capacity of 150 kg.
Suitable for users up to approximately 6.5 ft tall.
Mains-powered 24 V electrical operating system.
Supplied fully assembled for convenient installation.
Ideal For
The Morecare Iris is suitable for selected individuals requiring assisted reclining, gradual upright positioning, or supported standing therapy, including people undergoing neurological rehabilitation, spinal cord injury rehabilitation, stroke rehabilitation, and prolonged-bed-rest recovery. Suitability and standing tolerance must be assessed by a qualified rehabilitation professional before use.
| Section | ### General Information |
|---|---|
| Product Name | Morecare Iris Electric Tilt Table with Reclining Backrest |
| Model | Iris |
| Product Type | Dual-Function Electric Rehabilitation Tilt Table |
| Maximum User Weight | 150 kg |
| Maximum User Height | 6.5 ft (Approximately 198 cm) |
| Operation | Electric, Mains-Powered |
| Recommended Environment | Hospitals, Rehabilitation Centres, Physiotherapy Clinics & Supervised Home Rehabilitation |
| Section | ### Dimensions & Construction |
| Table Length | 6.5 ft (Approximately 198 cm) |
| Cushioned Surface Width | 30 Inches (Approximately 76 cm) |
| Floor-to-Cushion Height | 22 Inches (Approximately 56 cm) |
| Cushion Thickness | 3 Inches (Approximately 7.6 cm) |
| Surface Height Adjustment | Fixed |
| Section | ### Electric Positioning System |
| Backrest Adjustment | 0°–85° from Horizontal |
| Whole-Table Tilt | 0°–90° from Horizontal |
| Adjustment Functions | Independently Controlled Electric Backrest & Whole-Table Tilt |
| Handset | Wired Handheld Controller |
| Handset Operation | Press-and-Hold, Movement Stops When Button Is Released |
| Power Supply | Mains-Powered |
| Operating System | 24 V |
| Battery Backup | Not Available |
| Section | ### Support & Positioning |
| Chest Support | Positioning Strap Included |
| Pelvic Support | Positioning Strap Included |
| Leg Support | Positioning Strap Included |
| Total Support Straps | 3 |
| Footplate | Fixed |
| Side Rails | Collapsible |
| Section | ### Wheels & Safety |
| Castor Wheels | 4 |
| Braking System | Individual Brakes on All Four Wheels |
| Emergency Stop | Not Available |
| Emergency Lowering | Not Available |
| Power Failure | Electric Repositioning Unavailable Until Power Is Restored |
| Section | ### Shipping & Warranty |
| Assembly | Supplied Fully Assembled |
| Warranty | 1 Year on Electrical Parts |
| Customization | Available on Request, Subject to Technical Feasibility |
| Section | ### What's Included in the Box |
| Included Components | Iris Electric Tilt Table, 3 Positioning Straps, Fixed Footplate, Collapsible Side Rails & Wired Handset |
Supported Lying & Resting
The Morecare Iris provides a horizontal cushioned platform for supported lying, resting, and preparation before rehabilitation positioning sessions. Its padded surface and accessible side rails allow caregivers to assist with positioning and strap fitting.
Raised-Backrest Positioning
The independently adjustable electric backrest allows the upper body to be raised from 0° to 85° while the main table remains horizontal. This provides supported reclining and raised upper-body positioning for selected therapy activities and comfort requirements.
Gradual Upright Positioning
The whole-table electric tilting mechanism allows rehabilitation professionals to gradually increase the user's position from horizontal toward upright standing. Intermediate angles can be selected according to the user's assessed tolerance and rehabilitation programme.
Supported Standing Therapy
The fixed footplate and chest, pelvic, and leg straps provide positioning support during upright tilting. Iris may be used for therapist-guided supported standing and weight-bearing activities where clinically appropriate. It is not designed for walking or gait training.
Neurological Rehabilitation
The Morecare Iris may be incorporated into rehabilitation programmes for selected individuals recovering from stroke, spinal cord injury, traumatic brain injury, or other neurological conditions where gradual upright positioning is recommended by the treating professional.
Caregiver-Assisted Positioning
Collapsible side rails provide access for assisted transfers, body positioning, and adjustment of the support straps. Independent electric positioning functions help reduce the need for manual adjustment of the backrest and table angle.
Suitable For
The Morecare Iris is intended for individuals requiring supported lying, reclining, gradual upright positioning, or standing tolerance training. It may be considered for neurological rehabilitation, spinal cord injury rehabilitation, stroke recovery, prolonged bed rest, and selected mobility limitations. Suitability depends on medical stability, body dimensions, standing tolerance, positioning requirements, and professional clinical assessment.
Clinical Benefits
Therapist-guided tilt-table rehabilitation may help users gradually adapt to upright positioning, participate in supported weight-bearing activities, and practise standing tolerance. The independently adjustable backrest provides additional positioning flexibility for selected rehabilitation and care requirements. Clinical outcomes vary according to the user's condition, tolerance, and individualized therapy programme.
Every user has different body measurements, positioning requirements, and rehabilitation goals. The Morecare Iris can be reviewed for selected custom modifications to improve comfort, support, and suitability for individual therapy requirements.
Our team works with caregivers, physiotherapists, occupational therapists, and rehabilitation professionals to identify the most appropriate configuration before ordering.
Available Customizations
- Cushioning modifications based on individual comfort and positioning requirements.
- Strap positioning adjustments for chest, pelvic, and lower-limb support.
- Additional positioning supports based on clinical recommendations.
- Selected modifications to accommodate specific body dimensions.
- Custom configuration requests subject to technical feasibility and safety assessment.
The standard model includes a fixed footplate and a fixed 22-inch floor-to-cushion height.
How It Works
- Share the user's age, height, weight, diagnosis, and rehabilitation goals.
- Provide relevant body measurements and positioning requirements.
- Share therapist recommendations or photographs when appropriate.
- Morecare reviews the requested modifications for compatibility and technical feasibility.
- Available options, additional charges, and expected delivery time are confirmed before order finalization.
Need Help Choosing the Right Configuration?
Contact the Morecare rehabilitation team with the user's measurements, positioning needs, and intended therapy activities. Our specialists can help assess the standard Iris configuration and discuss available modifications before purchase.
- Always operate the Morecare Iris under the supervision of a qualified rehabilitation professional or appropriately trained caregiver.
- Apply all four castor brakes before transfers, positioning adjustments, or tilting.
- Secure the chest, pelvic, and leg straps before beginning any whole-table tilting movement.
- Ensure the user's feet are correctly positioned against the fixed footplate during supported upright positioning.
- Check that collapsible side rails are securely locked when raised.
- Do not rely on side rails as substitutes for the supplied body-support straps.
- Use the wired handset only while continuously observing the user and the moving platform.
- Release the handset button immediately if the user experiences discomfort or an unsafe position develops.
- Keep hands, clothing, bedding, medical tubing, and electrical cables away from hinges and moving mechanisms.
- Do not exceed the maximum user weight of 150 kg.
- Use only on a stable, level indoor surface.
- Never leave a user unattended while positioned on the table.
- Do not use the product for walking, gait training, or unsupported standing.
- The unit does not include an emergency-stop button, battery backup, or emergency lowering mechanism.
- During a power failure, electric repositioning and return to horizontal are unavailable until mains power is restored. A supervised contingency plan should be established before treatment.
- Do not begin tilting until the user's medical stability, tolerance, and positioning requirements have been assessed.
Product Life & Maintenance
- Regularly inspect the frame, support straps, side rail locks, footplate, fasteners, castors, and brakes.
- Check the handset, power cable, and electrical connections for visible damage before use.
- Clean the cushioned surface with a soft damp cloth and mild cleaning solution suitable for the upholstery.
- Avoid abrasive cleaners, solvents, and excessive moisture.
- Keep liquids away from the handset, actuator, and electrical components.
- Keep castor wheels clean and free from dust, hair, and debris.
- Use genuine Morecare spare parts and compatible replacement components.
- Arrange professional servicing if unusual movement, noise, electrical malfunction, instability, or structural damage is observed.
- Disconnect the equipment from mains power before cleaning or maintenance where required by the supplied instructions.
Important Clinical Information
- Tilt-table therapy should follow an individualized rehabilitation plan prescribed by a qualified healthcare professional.
- Standing angle and duration should be determined according to the user's medical condition and tolerance.
- Users with cardiovascular instability, significant orthostatic intolerance, unstable fractures, or other relevant medical concerns require professional assessment before upright positioning.
- The Morecare Iris provides assisted positioning and supported standing; it does not replace a hospital bed, walking aid, or gait trainer.
- Because the product has no emergency lowering or battery backup, facilities and caregivers must account for power interruption and safe user management before beginning therapy.
Warranty
- 1-year manufacturer warranty covering electrical parts against manufacturing defects under normal operating conditions.
- Warranty is valid from the date of purchase and requires a valid purchase invoice for all warranty claims.
- Warranty claims are subject to Morecare's applicable warranty terms and inspection.
- Normal wear and tear, misuse, accidental damage, improper maintenance, unauthorized electrical repairs, and unauthorized modifications are not covered unless otherwise specified in the warranty policy.
- Use of non-genuine or incompatible replacement parts may affect warranty eligibility and product performance.
Shipping & Assembly
- The Morecare Iris is supplied fully assembled.
- Delivery availability, shipping charges, and estimated delivery time are confirmed when placing the order.
- Customers should verify doorway widths, room access, and available installation space before ordering.
- Before first use, inspect the frame, cushioned surface, straps, side rails, footplate, wheels, brakes, and electrical controls.
After-Sales Support
- Lifetime virtual technical support via phone or video call.
- Guidance for product setup, positioning, and safe operation.
- Assistance with wired handset operation and electrical troubleshooting.
- Genuine Morecare spare parts and replacement components are available separately.
- Support for customization requests and additional positioning accessories.
- Preventive maintenance guidance for long-term product performance.
- Paid repair and servicing are available after the warranty period.
- Service availability and applicable charges are confirmed by the Morecare support team.
Need Assistance?
Contact the Morecare support team with your purchase invoice and product details for assistance with operation, troubleshooting, warranty claims, servicing, genuine spare parts, and customization requests. Our team can also guide caregivers and rehabilitation professionals on the appropriate setup and operation of the Morecare Iris.
Product Showcase & Reviews
Watch clinical insights and customer experiences.
Every Choice Has a Story
Choosing the right rehabilitation equipment is about finding the right fit for your family. Read why families chose this product
FAQs related to Iris - Electric Tilt Table with Reclining Backrest
Find quick answers to common questions about this product.
Yes. The Morecare Iris combines a horizontal cushioned platform, an electrically adjustable reclining backrest, and a whole-table tilting mechanism. It supports lying, raised-backrest positioning, and gradual tilting toward upright standing under professional supervision. It is not designed for walking or gait training.
Yes. The Morecare Iris features two independently controlled electric positioning functions. The backrest adjusts from **0° to 85°**, while the complete table tilts from **0° to 90°**, measured from horizontal. Both functions operate through a wired handset, and movement stops immediately when the control button is released.
The Morecare Iris supports a maximum user weight of **150 kg** and a maximum user height of approximately **6.5 ft (198 cm)**. The cushioned surface measures approximately 6.5 ft long and 30 inches wide, with a 3-inch cushion thickness. Individual body measurements and positioning needs should be reviewed before purchase.
No. The Morecare Iris operates through mains electricity using a **24 V operating system** and does not include battery backup. During a power failure, electric repositioning and return to horizontal are unavailable until power is restored. The standard model also does not include an emergency-stop button or backup lowering mechanism. A supervised power-failure contingency plan is essential before use.
The Morecare Iris includes **three positioning straps for the chest, pelvis, and legs**, a fixed footplate, collapsible side rails, and four castor wheels with individual brakes. The wired handset uses press-and-hold operation for controlled movement. The straps must be correctly fitted, and all four wheel brakes applied before tilting.
The Morecare Iris is **supplied fully assembled**, so no major on-site assembly is required. It includes a **1-year manufacturer warranty on electrical parts**, subject to the applicable warranty terms. Morecare also provides technical guidance, genuine spare parts, and paid repair and servicing support. Delivery availability and timelines are confirmed when placing the order.
Need Help Finding the
Right Solution?
Our rehabilitation experts are here to help you choose the right product or create a customized solution tailored to your needs.